Improved M112 handling
Use new synchronized sending method and also make sure that heaters will get disabled in case M112 is NOT understood by the firmware before disconnecting. That's about all we can do for now.
This commit is contained in:
parent
f8e72c9233
commit
5406b2bab1
1 changed files with 10 additions and 1 deletions
|
|
@ -1840,7 +1840,16 @@ class MachineCom(object):
|
||||||
def _gcode_M112_queuing(self, cmd, cmd_type=None):
|
def _gcode_M112_queuing(self, cmd, cmd_type=None):
|
||||||
# emergency stop, jump the queue with the M112
|
# emergency stop, jump the queue with the M112
|
||||||
self._doSendWithoutChecksum("M112")
|
self._doSendWithoutChecksum("M112")
|
||||||
self._doSendWithChecksum("M112", self._currentLine)
|
self._doIncrementAndSendWithChecksum("M112")
|
||||||
|
|
||||||
|
# No idea if the printer is still listening or if M112 won. Just in case
|
||||||
|
# we'll now try to also manually make sure all heaters are shut off - better
|
||||||
|
# safe than sorry. We do this ignoring the queue since at this point it
|
||||||
|
# is irrelevant whether the printer has sent enough ack's or not, we
|
||||||
|
# are going to shutdown the connection in a second anyhow.
|
||||||
|
for tool in range(self._printerProfileManager.get_current_or_default()["extruder"]["count"]):
|
||||||
|
self._doIncrementAndSendWithChecksum("M104 T{tool} S0".format(tool=tool))
|
||||||
|
self._doIncrementAndSendWithChecksum("M140 S0")
|
||||||
|
|
||||||
# close to reset host state
|
# close to reset host state
|
||||||
self._errorValue = "Closing serial port due to emergency stop M112."
|
self._errorValue = "Closing serial port due to emergency stop M112."
|
||||||
|
|
|
||||||