Changed configuration values to better ones, according to my experience, which should also help avoid missing steps

This commit is contained in:
Emanuele Caruso 2011-05-23 20:03:47 +02:00
parent 006407585e
commit 1139131f72

View file

@ -27,8 +27,8 @@
//Acceleration settings
#ifdef RAMP_ACCELERATION
//X, Y, Z, E maximum start speed for accelerated moves. E default values are good for skeinforge 40+, for older versions raise them a lot.
float max_start_speed_units_per_second[] = {35.0,35.0,0.2,10.0};
long max_acceleration_units_per_sq_second[] = {750,750,50,4000}; // X, Y, Z and E max acceleration in mm/s^2 for printing moves or retracts
float max_start_speed_units_per_second[] = {25.0,25.0,0.2,10.0};
long max_acceleration_units_per_sq_second[] = {3000,3000,50,10000}; // X, Y, Z and E max acceleration in mm/s^2 for printing moves or retracts
long max_travel_acceleration_units_per_sq_second[] = {1500,1500,50}; // X, Y, Z max acceleration in mm/s^2 for travel moves
#endif
#ifdef EXP_ACCELERATION
@ -54,10 +54,10 @@ float min_constant_speed_units = 2; // the minimum units of an accelerated move
#endif
//How often should the heater check for new temp readings, in milliseconds
#define HEATER_CHECK_INTERVAL 50
#define HEATER_CHECK_INTERVAL 500
#define BED_CHECK_INTERVAL 5000
//Uncomment the following line to disable heat management during acceleration
//#define DISABLE_CHECK_DURING_ACC
//Comment the following line to enable heat management during acceleration
#define DISABLE_CHECK_DURING_ACC
#ifndef DISABLE_CHECK_DURING_ACC
//Uncomment the following line to disable heat management during the move
//#define DISABLE_CHECK_DURING_MOVE