Changed configuration values to better ones, according to my experience, which should also help avoid missing steps
This commit is contained in:
parent
006407585e
commit
1139131f72
1 changed files with 5 additions and 5 deletions
|
|
@ -27,8 +27,8 @@
|
|||
//Acceleration settings
|
||||
#ifdef RAMP_ACCELERATION
|
||||
//X, Y, Z, E maximum start speed for accelerated moves. E default values are good for skeinforge 40+, for older versions raise them a lot.
|
||||
float max_start_speed_units_per_second[] = {35.0,35.0,0.2,10.0};
|
||||
long max_acceleration_units_per_sq_second[] = {750,750,50,4000}; // X, Y, Z and E max acceleration in mm/s^2 for printing moves or retracts
|
||||
float max_start_speed_units_per_second[] = {25.0,25.0,0.2,10.0};
|
||||
long max_acceleration_units_per_sq_second[] = {3000,3000,50,10000}; // X, Y, Z and E max acceleration in mm/s^2 for printing moves or retracts
|
||||
long max_travel_acceleration_units_per_sq_second[] = {1500,1500,50}; // X, Y, Z max acceleration in mm/s^2 for travel moves
|
||||
#endif
|
||||
#ifdef EXP_ACCELERATION
|
||||
|
|
@ -54,10 +54,10 @@ float min_constant_speed_units = 2; // the minimum units of an accelerated move
|
|||
#endif
|
||||
|
||||
//How often should the heater check for new temp readings, in milliseconds
|
||||
#define HEATER_CHECK_INTERVAL 50
|
||||
#define HEATER_CHECK_INTERVAL 500
|
||||
#define BED_CHECK_INTERVAL 5000
|
||||
//Uncomment the following line to disable heat management during acceleration
|
||||
//#define DISABLE_CHECK_DURING_ACC
|
||||
//Comment the following line to enable heat management during acceleration
|
||||
#define DISABLE_CHECK_DURING_ACC
|
||||
#ifndef DISABLE_CHECK_DURING_ACC
|
||||
//Uncomment the following line to disable heat management during the move
|
||||
//#define DISABLE_CHECK_DURING_MOVE
|
||||
|
|
|
|||