Added Fan control
This commit is contained in:
parent
85fe968aeb
commit
38afe46c0b
1 changed files with 19 additions and 3 deletions
|
|
@ -20,6 +20,8 @@
|
|||
//RepRap M Codes
|
||||
// M104 - Set target temp
|
||||
// M105 - Read current temp
|
||||
// M106 - Fan on
|
||||
// M107 - Fan off
|
||||
// M109 - Wait for current temp to reach target temp.
|
||||
|
||||
//Custom M Codes
|
||||
|
|
@ -301,6 +303,12 @@ inline void process_commands()
|
|||
manage_heater();
|
||||
}
|
||||
break;
|
||||
case 106: //M106 Fan On
|
||||
digitalWrite(FAN_PIN, HIGH);
|
||||
break;
|
||||
case 107: //M107 Fan Off
|
||||
digitalWrite(FAN_PIN, LOW);
|
||||
break;
|
||||
case 80: // M81 - ATX Power On
|
||||
if(PS_ON_PIN > -1) pinMode(PS_ON_PIN,OUTPUT); //GND
|
||||
break;
|
||||
|
|
@ -511,8 +519,16 @@ inline void manage_heater()
|
|||
current_raw = analogRead(TEMP_0_PIN); // If using thermistor, when the heater is colder than targer temp, we get a higher analog reading than target,
|
||||
if(USE_THERMISTOR) current_raw = 1023 - current_raw; // this switches it up so that the reading appears lower than target for the control logic.
|
||||
|
||||
if(current_raw >= target_raw) digitalWrite(HEATER_0_PIN,LOW);
|
||||
else digitalWrite(HEATER_0_PIN,HIGH);
|
||||
if(current_raw >= target_raw)
|
||||
{
|
||||
digitalWrite(HEATER_0_PIN,LOW);
|
||||
digitalWrite(LED_PIN,LOW);
|
||||
}
|
||||
else
|
||||
{
|
||||
digitalWrite(HEATER_0_PIN,HIGH);
|
||||
digitalWrite(LED_PIN,HIGH);
|
||||
}
|
||||
}
|
||||
|
||||
// Takes temperature value as input and returns corresponding analog value from RepRap thermistor temp table.
|
||||
|
|
@ -599,4 +615,4 @@ inline void kill(byte debug)
|
|||
}
|
||||
}
|
||||
|
||||
inline void manage_inactivity(byte debug) { if( (millis()-previous_millis_cmd) > max_inactive_time ) if(max_inactive_time) kill(debug); }
|
||||
inline void manage_inactivity(byte debug) { if( (millis()-previous_millis_cmd) > max_inactive_time ) if(max_inactive_time) kill(debug); }
|
||||