Disable TEMP_RESIDENCY_TIME for default

This commit is contained in:
Lawrence Leung larryleungcal@yahoo.com 2011-07-25 00:55:42 -07:00
parent 067c662510
commit eb1c87fa7b

View file

@ -16,12 +16,14 @@
// 2 is 200k thermistor
// 3 is mendel-parts thermistor
// 4 is 10k thermistor
#define THERMISTORHEATER 1
#define THERMISTORBED 1
// 5 is Ultimachine
// 6 is honeywell
#define THERMISTORHEATER 5
#define THERMISTORBED 6
//// Calibration variables
// X, Y, Z, E steps per unit - Metric Prusa Mendel with Wade extruder:
float axis_steps_per_unit[] = {80, 80, 3200/1.25,700};
float axis_steps_per_unit[] = {32.37655, 32.37655, 642,144.31/2};
// Metric Prusa Mendel with Makergear geared stepper extruder:
//float axis_steps_per_unit[] = {80,80,3200/1.25,1380};
@ -36,7 +38,7 @@ const bool ENDSTOPS_INVERTING = false; //set to true to invert the logic of the
#define BAUDRATE 115200
// Comment out (using // at the start of the line) to disable SD support:
#define SDSUPPORT 1
//#define SDSUPPORT 1
//// ADVANCED SETTINGS - to tweak parameters
@ -101,7 +103,7 @@ long max_travel_acceleration_units_per_sq_second[] = {500,500,50,500}; // X, Y,
// Machine UUID
// This may be useful if you have multiple machines and wish to identify them by using the M115 command.
// By default we set it to zeros.
char uuid[] = "00000000-0000-0000-0000-000000000000";
char uuid[] = "00000000-0000-0000-0000-000000000123";
//// AD595 THERMOCOUPLE SUPPORT UNTESTED... USE WITH CAUTION!!!!
@ -119,7 +121,7 @@ char uuid[] = "00000000-0000-0000-0000-000000000000";
// How often should the heater check for new temp readings, in milliseconds
#define HEATER_CHECK_INTERVAL 500
#define BED_CHECK_INTERVAL 5000
#define BED_CHECK_INTERVAL 2000
// Comment the following line to enable heat management during acceleration
#define DISABLE_CHECK_DURING_ACC
#ifndef DISABLE_CHECK_DURING_ACC
@ -141,7 +143,7 @@ char uuid[] = "00000000-0000-0000-0000-000000000000";
//#define WATCHPERIOD 5000 //5 seconds
// Wait this long after achieving target temperature on M109 before continuing with print (seconds)
#define TEMP_RESIDENCY_TIME 20
//#define TEMP_RESIDENCY_TIME 20
//// The minimal temperature defines the temperature below which the heater will not be enabled
#define MINTEMP 5
@ -150,7 +152,7 @@ char uuid[] = "00000000-0000-0000-0000-000000000000";
// When temperature exceeds max temp, your heater will be switched off.
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
// You should use MINTEMP for thermistor short/failure protection.
#define MAXTEMP 275
#define MAXTEMP 250
// Select one of these only to define how the nozzle temp is read.
#define HEATER_USES_THERMISTOR