Merge branch 'fix/breaks-bug' into 'master'
Fixed lunch break bugs See merge request cara/cara!120
This commit is contained in:
commit
4715005b77
5 changed files with 17 additions and 7 deletions
|
|
@ -326,11 +326,12 @@ class FormData:
|
|||
present_intervals.append((time / 60, finish / 60))
|
||||
break
|
||||
|
||||
if leave_times[-1] <= time:
|
||||
if leave_times[-1] < time:
|
||||
leave_times.pop()
|
||||
else:
|
||||
new_time = leave_times.pop()
|
||||
present_intervals.append((time / 60, min(new_time, finish) / 60))
|
||||
if time / 60 != min(new_time, finish) / 60 :
|
||||
present_intervals.append((time / 60, min(new_time, finish) / 60))
|
||||
is_present = False
|
||||
time = new_time
|
||||
|
||||
|
|
|
|||
|
|
@ -292,8 +292,8 @@ function validate_form(form) {
|
|||
|
||||
//Validate all lunch breaks
|
||||
if (submit) {
|
||||
$("input[required].lunch").each(function() {
|
||||
if (!validateLunchBreak(this)) {
|
||||
$("input[required].start_time[data-lunch-for]").each(function() {
|
||||
if (!validateLunchBreak($(this).data('time-group'))) {
|
||||
submit = false;
|
||||
}
|
||||
});
|
||||
|
|
|
|||
|
|
@ -219,7 +219,7 @@
|
|||
<b>Ventilation data:</b> <br>
|
||||
<ul>
|
||||
<li>Mechanical ventilation = the HVAC supply of fresh air. Check the flow rates with the concerned technical department.</li>
|
||||
<li>Natural ventilation = the type of window opening. The opening distance is between the fixed frame and movable part when open (commonly used values are window opening between 0.6 and 0.15 m). In case of periodic opening, specify the duration (e.g. for 10 min) and frequency (e.g. every 60 min).</li>
|
||||
<li>Natural ventilation = the type of window opening. The opening distance is between the fixed frame and movable part when open (commonly used values are window height of 1.6m and window opening between 0.15m and 0.6m). In case of periodic opening, specify the duration (e.g. for 10 min) and frequency (e.g. every 60 min).</li>
|
||||
<li>HEPA filtration = the air flow of the device. The following values are based on the different fan velocities of a specific commercial device proposed by the HSE Unit:</li>
|
||||
<ul>
|
||||
<li>Level 6 (max) = 430 m<sup>3</sup>/h (noisy)</li>
|
||||
|
|
|
|||
|
|
@ -107,11 +107,11 @@
|
|||
Gym = For comparison only, all persons doing heavy physical exercise, breathing and not talking.
|
||||
{% endif %}
|
||||
</p></li>
|
||||
<li><p class="data_text">Presence of exposed occupant(s):</p></li>
|
||||
<li><p class="data_text">Exposed occupant(s) activity time:</p></li>
|
||||
<ul>
|
||||
<li><p class="data_subtext">Start time: {{ form.activity_start | minutes_to_time }}    End time: {{ form.activity_finish | minutes_to_time }}</p></li>
|
||||
</ul>
|
||||
<li><p class="data_text">Presence of infected occupant(s):</p></li>
|
||||
<li><p class="data_text">Infected occupant(s) activity time:</p></li>
|
||||
<ul>
|
||||
<li><p class="data_subtext">Start time: {{ form.infected_start | minutes_to_time }}    End time: {{ form.infected_finish | minutes_to_time }}</p></li>
|
||||
</ul>
|
||||
|
|
|
|||
|
|
@ -161,6 +161,15 @@ def test_exposed_present_intervals(baseline_form):
|
|||
correct = ((9, 10+37/60), (10+52/60, 12.5), (13.5, 15+7/60), (15+22/60, 17.0))
|
||||
assert baseline_form.exposed_present_interval().present_times == correct
|
||||
|
||||
def test_exposed_present_intervals_starting_with_lunch(baseline_form):
|
||||
baseline_form.coffee_breaks = 0
|
||||
baseline_form.activity_start = baseline_form.lunch_start = 13 * 60
|
||||
baseline_form.activity_finish = 18 * 60
|
||||
baseline_form.lunch_finish = 14 * 60
|
||||
baseline_form.infected_start = 9 * 60
|
||||
baseline_form.infected_finish = 13 * 60
|
||||
correct = ((14.0, 18.0),)
|
||||
assert baseline_form.exposed_present_interval().present_times == correct
|
||||
|
||||
def test_coffee_lunch_breaks(baseline_form):
|
||||
baseline_form.coffee_duration = 30
|
||||
|
|
|
|||
Loading…
Reference in a new issue