Adding tests for multiple ventilation

This commit is contained in:
Nicolas Mounet 2020-11-05 18:42:05 +01:00
parent b36e07e0b9
commit f271b29ae1

View file

@ -143,6 +143,56 @@ def test_periodic_hepa(baseline_periodic_hepa, baseline_room):
npt.assert_allclose(aes, answers, rtol=1e-5)
@pytest.mark.parametrize(
"time, expected_value",
[
[0, 3.7393925],
[14 / 60, 514.74 / 68 + 3.7393925],
[15 / 60, 514.74 / 68 + 3.7393925],
[16 / 60, 3.7393925],
[1, 5.3842316],
[1.5, 514.74 / 68 + 5.3842316],
[121 / 60, 514.74 / 68 + 5.3842316],
[2.5, 5.3842316],
],
)
def test_multiple_ventilation_HEPA_window(baseline_periodic_hepa, time, expected_value):
room = models.Room(volume=68.)
tempOutside = models.PiecewiseConstant((0,1,2.5),(273.15,283.15))
tempInside = models.PiecewiseConstant((0,24),(293.15,))
window = models.WindowOpening(active=models.SpecificInterval([(0,24)]),
inside_temp=tempInside,outside_temp=tempOutside,
window_height=1.,opening_length=0.6)
vent = models.MultipleVentilation(window, baseline_periodic_hepa)
npt.assert_allclose(vent.air_exchange(room,time), expected_value, rtol=1e-5)
@pytest.mark.parametrize(
"volume, expected_value",
[
[24.5, 500 / 24.5 + 100 / 24.5 + 3.],
[70, 500 / 70 + 100 / 70 + 3.],
],
)
def test_multiple_ventilation_HEPA_HVAC_AirChange(volume, expected_value):
room = models.Room(volume=volume)
hepa = models.HEPAFilter(
active=models.SpecificInterval([(0,24)]),
q_air_mech=500.,
)
hvac = models.HVACMechanical(
active=models.SpecificInterval([(0,24)]),
q_air_mech=100.,
)
airchange = models.AirChange(
active=models.SpecificInterval([(0,24)]),
air_exch=3.,
)
vent = models.MultipleVentilation(hepa, hvac, airchange)
npt.assert_allclose(vent.air_exchange(room,10.),
expected_value,rtol=1e-5)
def test_expiration_aerosols():
mask = models.Mask.types['Type I']
exp1 = models.Expiration((0.751, 0.139, 0.0139, 0.059),