Fix wrong emission rate in test_monte_carlo_full_models.py::test_small_shared_office_Geneva; decrease tolerance and number of samples subsequently
This commit is contained in:
parent
987454928c
commit
f99dcc5e0c
1 changed files with 3 additions and 3 deletions
|
|
@ -9,8 +9,8 @@ from cara.apps.calculator.model_generator import build_expiration
|
|||
|
||||
# TODO: seed better the random number generators
|
||||
np.random.seed(2000)
|
||||
SAMPLE_SIZE = 600_000
|
||||
TOLERANCE = 0.06
|
||||
SAMPLE_SIZE = 500_000
|
||||
TOLERANCE = 0.05
|
||||
|
||||
# Load the weather data (temperature in kelvin) for Toronto.
|
||||
toronto_coordinates = (43.667, 79.400)
|
||||
|
|
@ -342,7 +342,7 @@ def test_report_models(mc_model, expected_pi, expected_new_cases,
|
|||
["No mask", "Jul", 9.52, 9.920, 809],
|
||||
["Type I", "Jul", 1.7, 0.913, 149],
|
||||
["FFP2", "Jul", 0.51, 0.239, 149],
|
||||
["Type I", "Feb", 0.57, 0.272, 162],
|
||||
["Type I", "Feb", 0.57, 0.272, 149],
|
||||
],
|
||||
)
|
||||
def test_small_shared_office_Geneva(mask_type, month, expected_pi,
|
||||
|
|
|
|||